Before starting the oil-free scroll compressor, check whether the ball valve of the power cord and the exhaust port is open. Check whether the lubricating oil inside the air compressor has been reduced. After starting, observe the operation of the machine. The temperature is relatively high at 180 Above the temperature, the maintenance consumables that the machine runs for a certain period of time are different. For example, 2000 hours of operation must be replaced with oil filters and air filters, and after 4000 hours, the air filters and oil filters and screw oils should be replaced. Afterwards, in the process of use, the maintenance cost will increase greatly as the running time increases.
Exhaust valve exhausts too much oil and gas, due to incomplete air compressor oil and gas separation, air compressor exhaust contains a small amount of oil molecules, exhaust valve exhaust gas for a long time will form a compact compressor host, motor, radiator and other sticky grime. It will not only affect the cleanliness of the whole machine, make the rubber-like components prematurely aging, but also cause the heat dissipation effect to drop and the temperature to be high to shut down. To this end, we use a 2m long 2 inch rubber tube to cover the exhaust valve and discharge the exhaust gas from the round hole of the bottom plate to the outside of the air compressor.
The following will introduce to you that the processing method of oil-free scroll compressor needs to be determined according to the time. If it is shut down for about one month, the condensate in the body must be discharged cleanly, because if it is left in the body for a long time Inside, it is simple to cause the equipment to be corroded. Check to see if there are any accessories that cannot be used normally. Damaged parts need to be replaced before being shut down. This is done for smooth operation when the machine is turned on again. The exterior dust of the radiator is blown clean with gas, and the exterior of the equipment is also scrubbed again.
When the shutdown time exceeds two months, not only to carry out the above, but also to wrap the important vulnerable parts such as the operation panel with corresponding oil paper. In addition, the entrance to the dirty entrance and exit should be blocked to avoid the entry of too much foreign matter. The air compressor oil must not be forgotten. Replace it before shutting down. It takes a lot of trouble to watch, but each process cannot be omitted. If the machine is not maintained properly when it is not in use, it will break faster than it is in operation.
The above is all the knowledge that Xiaobian brings to everyone today, I hope it can help you.

Hangzhou Scala Filtration Technology Co.,Ltd

Main: compressed air filter,air water separator, liquid nitrogen generator

Fax:

Email: sales@scala-filtration.com

Address: Room 110,Building 1, Kaiyuan Yisu, Liangzhu Street, Yuhang, Hangzhou, Zhejiang, China

©2024 Hangzhou Scala Filtration Technology Co., Ltd.   Record number:浙ICP备15045093号-6   Login  Sitemap

service Phone QR code

Service Hotline

+86-13758206140

Scan and follow us