Air compressor is a device used to compress gas. According to different classification methods, we can divide it into the following types:
1.Classified by working principle: volumetric air compressor, power air compressor, thermal compressor.
2.Classified by performance: low noise air compressor, variable frequency air compressor, explosion-proof air compressor.
3.Classified by type: fixed air compressor, mobile air compressor, closed air compressor.
Product composition of air compressor:
1.Oil circulation system: Before starting, first start the oil pump control system. After the oil pump control system is started, ensure that the lubrication parts of the air compressor are well lubricated. At the same time, the oil pump control system can adjust the internal oil pressure and oil temperature through the built-in temperature control valve. Meet system needs.
2.Water circulation system: The cooling water enters the intercooler of the air compressor through the pipeline to cool down the first-stage compressed exhaust gas, and then enters the aftercooler to cool the exhaust. The group heat exchanger cools the motor windings, and there is a way to cool the oil cooler.
3.Air circulation system: When the compressor is working, the air is sucked in through the self-cleaning air filter, and the filter is automatically cleaned by PLC. After the air is automatically adjusted by the inlet guide vane, the air enters the first stage compression, and the gas temperature after the first stage compression Higher, and then enter the intercooler for cooling (in the water pipe, outside the gas pipe, the water flow of the intercooler is required to be 110m / h), and then enter the secondary compression system, in order to prevent the gas in the system from pouring into the compression chamber. The exhaust pipe of the compressor is equipped with a hanging full-open check valve. The gas discharged by the compressor pushes the check valve into the exhaust muffler, then enters the first-stage aftercooler, the second-stage aftercooler, and then enters the exhaust. The main pipeline.
4.Power distribution system: The air compressor is a 2000kW high-voltage motor (10kV) with full voltage start, the control cabinet is indoor AC, metal armored withdrawable switchgear. The switchgear consists of a fixed cabinet and extractable components, namely the handcart. It is composed of parts to achieve the purpose of control, protection and monitoring, and has the function of "five defenses".
5.Screen protection system: The central signal device is divided into two types: accident signal and notice signal. The main task of the accident signal is to be able to send out an acoustic signal in time when the circuit breaker accidentally trips, and make the corresponding circuit breaker light position signal flash. The main task of the notice signal is to issue an acoustic signal instantaneously or delayed when an abnormal phenomenon occurs in the operating equipment, and to make the light word plate display the content of the abnormal phenomenon.
6.DC power supply system: PZ32 series full-automatic maintenance-free lead-acid battery DC power supply complete set of equipment, consisting of a charging device screen, a DC feed screen, and a battery, with functions such as automatic current stabilization, automatic voltage stabilization, and automatic voltage regulation, which are central signal screen And high voltage control system.
7.DTC control system: The DTC control screen is the "brain" of the air compressor. The values of various on-site sensors are finally summarized in the DTC control screen, various operating parameters are displayed on the DTC control screen, and the operation of each part of the air compressor is monitored. State, when some parameters exceed the allowable range, DTC will issue corresponding alarm or automatically stop the air compressor.
Hangzhou Scala Filtration Technology Co.,Ltd
Main: compressed air filter,air water separator, liquid nitrogen generator
Fax:
Email: sales@scala-filtration.com
Address: Room 110,Building 1, Kaiyuan Yisu, Liangzhu Street, Yuhang, Hangzhou, Zhejiang, China